The WELL.DONE DTS system simultaneously monitors thousands of locations along the entire length of an onshore and offshore well.
Detection of well temperature profiles, reservoir monitoring, optimization of production and prevention of any unwanted operation conditions are examples of key functions of the temperature monitoring system. With its high optical budget and, it is virtually insensitive to high optical power losses associated with splice losses, subsea connectors and penetrators, and hydrogen darkening of optical fibers under the harsh conditions within a wellbore.
Applications
- Deep offshore wells
- Subsea wells
- Hydrogen darkened fibers
- Wet-mate connection wells
- Subsea Monitoring
- ROV umbilicals
- Risers
Contact us now
Distance ranges of WELL.DONE DTS models
WELL.DONE -050, -100, -200, -300, -400, -500, -600, -700 |
5 km, 10 km, 20 km, 30 km 40 km, 50 km, 60 km, 70 km |
Data Storage / Communication / Interfaces
I/O board (optional*) |
4 inputs / 12 outputs |
Analogue sensors interface board (optional*) |
4x Pt100, 2x 0(4)-20mA and 2x 0-10V |
*2 optional internal boards can be installed in total
Optical data
Optical channels (internal) |
1, 2, 3, 4, 6, 8, 9, 12 or 16 |
Fiber configuration |
No loop or termination required |
Optical connector(s) |
E2000 / APC |
Fiber type |
Single-mode 9/125 |
Laser classification |
Class 1M (IEC60825-1), eye-safe wavelength |
Measurement performance*
Sampling interval |
0.25, 0.5 or 1 m |
Spatial resolution |
1, 2, 3 or 5 m |
Temperature resolution, minimum |
< 0.1 °C |
Temperature resolution @ 10dB optical loss |
< 1 °C |
Temperature accuracy |
2 °C** |
Measurement time |
1 to 20 min |
* Measurement performance parameters are interdependent
** After calibration on a loose fiber without strain
Data Storage / Communication / Interfaces
Internal SSD storage |
8, 16, 32 or 64 GB |
Communication interfaces |
2x Ethernet TCP/IP, USB, (optional: WLAN, GSM) |
Communication protocols (options) |
XML, MODBUS, DNP3, IEC60870, IEC61850 |
Programmable inputs / outputs |
4 / 10 |
Fixed outputs |
Collective fault and alarm |
Analogue outputs (optional external module) |
4 - 20mA |
Mechanical data
Rack space |
19-inch rack, 3 height units |
Dimensions (H x W x D) |
13.3 x 43.9 x 40.3 cm |
Weight |
15 kg |
Electrical data
Power consumption, max. (DC / AC options) |
40W / 45W |
Operating voltage (DC-1 option) |
12 … 24 V DC (-15%/+10%) |
Operating voltage (DC-2 option) |
24 … 48 V DC (-15%/+10%) |
Mains voltage (AC option) |
100 … 240 V AC 50..60 Hz / 110… 220 V DC (-15%/+10%) |
Environmental Conditions
Storage temperature |
-40°C to +85°C |
Operating temperature |
-10°C to +60°C |
Humidity (relative) |
≤95 % (non-condensing) |
Protection class (IEC 60529) |
IP51 |
Conformity to Standards
Electrical safety |
IEC/UL 61010-1, LV directive 2014/35/EC, CAN/CSA-C22.2 |
EMC* |
EN61326-1, EN61000-6-2,3,-4-2,3,4,5,6,8,11,-3-2,3, FCC 47 CFR Ch.1 Part15 |
Hazardous substances, waste |
RoHS directive 2011/65/EC, WEEE directive 2002/96/EC |
Functional safety (IEC61508)* |
Hardware design compliant to Safety Integrity Level SIL2 |
Explosion safety (option)* |
EX II (1) G [Ex op is T4 Ga] IIC / II (1) D [Ex op is Da] IIIC / I (M1) [Ex op is Ma] |
*Qualification in process