LIOS WELL.DONE High Optical Budget Distributed Temperature Sensing

The WELL.DONE DTS system simultaneously monitors thousands of locations along the entire length of an onshore and offshore well.

Detection of well temperature profiles, reservoir monitoring, optimization of production and prevention of any unwanted operation conditions are examples of key functions of the temperature monitoring system. With its high optical budget and, it is virtually insensitive to high optical power losses associated with splice losses, subsea connectors and penetrators, and hydrogen darkening of optical fibers under the harsh conditions within a wellbore.

Applications

  • Deep offshore wells
  • Subsea wells
  • Hydrogen darkened fibers
  • Wet-mate connection wells
  • Subsea Monitoring
  • ROV umbilicals
  • Risers

Contact us now

Distance ranges of WELL.DONE DTS models

WELL.DONE -050, -100, -200, -300, -400, -500, -600, -700 5 km, 10 km, 20 km, 30 km 40 km, 50 km, 60 km, 70 km

Data Storage / Communication / Interfaces

I/O board (optional*) 4 inputs / 12 outputs
Analogue sensors interface board (optional*) 4x Pt100, 2x 0(4)-20mA and 2x 0-10V

*2 optional internal boards can be installed in total

Optical data

Optical channels (internal) 1, 2, 3, 4, 6, 8, 9, 12 or 16
Fiber configuration No loop or termination required
Optical connector(s) E2000 / APC
Fiber type Single-mode 9/125
Laser classification Class 1M (IEC60825-1), eye-safe wavelength

Measurement performance*

Sampling interval 0.25, 0.5 or 1 m
Spatial resolution 1, 2, 3 or 5 m
Temperature resolution, minimum < 0.1 °C
Temperature resolution @ 10dB optical loss < 1 °C
Temperature accuracy 2 °C**
Measurement time 1 to 20 min

* Measurement performance parameters are interdependent
** After calibration on a loose fiber without strain

Data Storage / Communication / Interfaces

Internal SSD storage 8, 16, 32 or 64 GB
Communication interfaces 2x Ethernet TCP/IP, USB, (optional: WLAN, GSM)
Communication protocols (options) XML, MODBUS, DNP3, IEC60870, IEC61850
Programmable inputs / outputs 4 / 10
Fixed outputs Collective fault and alarm
Analogue outputs (optional external module) 4 - 20mA

Mechanical data

Rack space 19-inch rack, 3 height units
Dimensions (H x W x D) 13.3 x 43.9 x 40.3 cm
Weight 15 kg

Electrical data

Power consumption, max. (DC / AC options) 40W / 45W
Operating voltage (DC-1 option) 12 … 24 V DC (-15%/+10%)
Operating voltage (DC-2 option) 24 … 48 V DC (-15%/+10%)
Mains voltage (AC option) 100 … 240 V AC 50..60 Hz / 110… 220 V DC (-15%/+10%)

Environmental Conditions

Storage temperature -40°C to +85°C
Operating temperature -10°C to +60°C
Humidity (relative) ≤95 % (non-condensing)
Protection class (IEC 60529) IP51

Conformity to Standards

Electrical safety IEC/UL 61010-1, LV directive 2014/35/EC, CAN/CSA-C22.2
EMC* EN61326-1, EN61000-6-2,3,-4-2,3,4,5,6,8,11,-3-2,3, FCC 47 CFR Ch.1 Part15
Hazardous substances, waste RoHS directive 2011/65/EC, WEEE directive 2002/96/EC
Functional safety (IEC61508)* Hardware design compliant to Safety Integrity Level SIL2
Explosion safety (option)* EX II (1) G [Ex op is T4 Ga] IIC / II (1) D [Ex op is Da] IIIC / I (M1) [Ex op is Ma]

*Qualification in process